diff options
author | 2020-05-21 22:07:52 +1000 | |
---|---|---|
committer | 2020-05-21 22:27:46 +1000 | |
commit | 52c7b830a9e11c3ae53b4930e2f4e48129f96cfc (patch) | |
tree | b033b742256a967d9dba90aff0d74d9485bf5f7e /scripts/build/file2str.py | |
parent | 60592a35f64c9b23650c779d5baa7d8fd18ea2bf (diff) |
mc6850: TDRE should read clear in reset, and set coming out of reset
Fixes a lockup running UniFlex on the SWTPC09.
Tested on hardware, the TDRE flag reads as zero in the reset state and
reads as set when taken out of reset, and even if data has been written
to the data register while in the reset state.
Diffstat (limited to 'scripts/build/file2str.py')
0 files changed, 0 insertions, 0 deletions