// license:BSD-3-Clause
// copyright-holders:Robbbert
/*
Micromon 7141 ECG unit for hospitals.
No manuals or schematic found.
From the photos, we can see a CDP1802ACE CPU, 2.4576 crystal,
a GM76C28A-10 2Kx8 static RAM (like 6116), 2 ROMS and a bunch of small chips.
There's also 4 dipswitches in a single package. 1=on,2=off,3=off,4=on.
The unit has an audible alarm, presumably a speaker, but it doesn't appear in any photo.
The front panel has a CRT display (looks like cyan on black), some buttons with unknown
symbols, a 5-position rotary switch, a plug for the ECG device, a socket called "Sync"
and some LEDs.
Date of manufacture unknown, however the chips have date codes of 1994 and 1995.
*****************************************************************************************/
#include "emu.h"
#include "cpu/cosmac/cosmac.h"
class micromon_state : public driver_device
{
public:
micromon_state(const machine_config &mconfig, device_type type, const char *tag)
: driver_device(mconfig, type, tag)
, m_maincpu(*this, "maincpu")
{ }
void micromon(machine_config &config);
private:
DECLARE_READ_LINE_MEMBER(clear_r);
void io_map(address_map &map);
void mem_map(address_map &map);
virtual void machine_reset() override;
uint8_t m_resetcnt = 0U;
required_device<cosmac_device> m_maincpu;
};
void micromon_state::mem_map(address_map &map)
{
map(0x0000, 0x1fff).rom();
map(0x2000, 0x3fff).ram();
}
void micromon_state::io_map(address_map &map)
{
}
static INPUT_PORTS_START( micromon )
INPUT_PORTS_END
READ_LINE_MEMBER( micromon_state::clear_r )
{
if (m_resetcnt < 0x10)
m_maincpu->set_state_int(cosmac_device::COSMAC_R0, 0x0000);
if (m_resetcnt < 0x20)
m_resetcnt++;
// set reset pin to normal
return 1;
}
void micromon_state::machine_reset()
{
m_resetcnt = 0;
}
void micromon_state::micromon(machine_config &config)
{
// basic machine hardware
CDP1802(config, m_maincpu, 2457600);
m_maincpu->set_addrmap(AS_PROGRAM, µmon_state::mem_map);
m_maincpu->set_addrmap(AS_IO, µmon_state::io_map);
m_maincpu->wait_cb().set_constant(1);
m_maincpu->clear_cb().set(FUNC(micromon_state::clear_r));
// video hardware
// sound
}
ROM_START( micromon7141 )
ROM_REGION( 0x2000, "maincpu", 0 )
ROM_LOAD( "721421_rev4.0_25_7_95.ic2", 0x0000, 0x1000, CRC(b2a26439) SHA1(66a65d19b3cff185e82b10fc7ecb965c51751b7c) )
ROM_LOAD( "702423_rev4.0_25_7_95.ic41", 0x1000, 0x1000, CRC(5efe6b4b) SHA1(b3670c53e2527e824cc22e4a54db9abf5a07239f) )
ROM_END
SYST( 1995?, micromon7141, 0, 0, micromon, micromon, micromon_state, empty_init, "Kontron Instruments", "Micromon 7141 ECG unit", MACHINE_IS_SKELETON | MACHINE_SUPPORTS_SAVE )
|